Test Case – To calculate ETTV of the test model
Instructions:
Please note Revit software
is required to run the Test case.
1.
Open the attached file, TESTCASE.rvt (http://www.bca.gov.sg/helios/testcase.rvt)
2.
The file is already preloaded with a simple apartment model and the
material library compatible with Helios.
3. A few rounds of preliminary testing
could be done with the tool:
a. Calculate
ETTV of the test model:
i) Click on Tools ---- External
tools ----- Calculate ETTV.
ii) The tool gives you the W/m2 heat
gain through the facades in the different orientations (Four cardinal and four
sub-cardinal directions included)
iii) Click Ok and the tool returns you
the final project ETTV value in W/m2.
b.
Change the orientation of the building and study the impact:
i) Go to the plan view of the
building and select the image
ii) Rotate the entire plan by 90 deg clockwise or
anticlockwise
iii) Repeat Step a and
find the impact on ETTV values.
c.
Change the Window-to-Wall ratio:
i) Click on
the east/west facade and remove the windows on the facade by selecting them and
deleting the same.
ii) Repeat Step a and
study the impact.
d. Change thermal properties of building
materials:
i) Select the edit materials
properties from the tools tab.
ii) Change the U-value of the wall/SC of glass of
the window
iii)
Repeat step a and study the impact.